Performance
INPUT 12V DC, 120A Max
NO LOAD CURRENT DRAW 0.8A
OUTPUT 230/240VAC, 50Hz (Modified Sine)
OUTPUT POWER 1000W Continuous (2000W Peak)
INVERTER CLASSIFICATION Equipotentially Bonded (EPB)
EFFICIENCY 85–90%
LOW BATTERY ALARM 10.5 Volt
SHUTDOWN 10.0 Volt (±0.2V)
COOLING FAN Automatic temperature controlled
Battery cable
1100mm 16mm2 battery cable
Twin power sockets
AS/NZS approved 240V sockets. Inverter designed to Australian standard AS4763
L.E.D indicators
Power and fault lights with audible alarm if problem is detected
Efficient design
Temperature controlled automatic cooling fan
Mounting flange
Convenient and robust mounting points
Manual in PDF HERE
SPECIFICATIONS | |||
---|---|---|---|
INPUT |
12V DC, 120A Max |
||
NO LOAD CURRENT DRAW |
0.8A |
||
OUTPUT |
230/240VAC, 50Hz (Modified Sine) |
||
OUTPUT POWER |
1000W Continuous (2000W Peak) |
||
INVERTER CLASSIFICATION |
Equipotentially Bonded (EPB) |
||
EFFICIENCY |
85–90% |
||
LOW BATTERY ALARM |
10.5 Volt |
||
SHUTDOWN |
10.0 Volt (±0.2V) |
||
COOLING FAN |
Automatic temperature controlled |
||
THERMAL SHUTDOWN |
65°C (±5°C) |
||
FUSE |
6 x 20A |
||
IDEAL BATTERY SIZE |
75–250Ah |
||
MINIMUM BATTERY SIZE |
75Ah, 550CCA |
||
RUN TIME WITH 1000W ON 75Ah BATTERY |
15 minutes |
||
RUN TIME WITH 100W GLOBE ON 75Ah BATTERY |
6 hours |
||
WARNING ALARM |
LED & Audible alarm indicates a fault |
||
APPROVALS |
Electrical Safety, EMC |
Details of the product above will be automatically included with your enquiry.